December 11, 2017

4-Up Vertical Forced Air and Catheter Shrink Machines

MACHINE NO. 5782

MACHINE 5782 – Up to 60 inch heat shrinkable catheters with a metal mandrel inserted is manually loaded into 1 of 4 air drawbar closed collets. Hot air nozzles mounted on a movable carriage transverse vertically down and back up over tubing applying an even flow of heat to the tubing. Temperature, airflow, transverse speed, and collet size are all variable.

MACHINE CONTROL – A solid state programmable controller operates the sequence with an easily accessible control panel including Main Power, Emergency Stop, Manual, Automatic, and individual Operations controls.

MACHINE NO. 5730

MACHINE 5730 – A catheter with heat shrinkable tubing over it is manually loaded onto 1 of 4 stationary heads. Air heaters mounted on a moveable carriage transverse vertically down and back up over tubing applying an even flow of heat to the tubing. Temperature, transverse speed are all variable.

MACHINE CONTROL – A solid state programmable controller operates the sequence with an easily accessible control panel including Main Power, Emergency Stop, Manual, Automatic, and individual Operations controls

 